This reverts commit cde2a77ed3.
Applying this change has shown that it is even quicker to provoke the
race condtition on simultan mwan3 commands execution.
By reversing the change we have the same behaviour as before.
But the race condition on mwan3 execute at the same time still exists.
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
(cherry picked from commit b5bd6d757b)
This adjustment of the locks fixes the race condition when a mwan3
hotplug script and a mwan3 command are running at the same time.
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
(cherry picked from commit 2dac1bcdc9)
Add also online time value and uptime time value from netifd to the
detail output view.
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
(cherry picked from commit b0acbf057e)
If the uci option family is not set in the interface section, then there
is no default value set as in the `config_load / config_get` API.
The problem here is that if the family is not set, the default value ipv4
is normaly assumed. But the comparison fails here because the value is empty
and therefore the dedicated routing table for this interface is not compared
with the other routes from the main table and so not updated.
To fix this set the default value for this config option which is`false`
for enabled and `ipv4` for family.
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
(cherry picked from commit bcd13ba95c)
This fixes routing handling. Introduced with the last version update.
The following message disappears on the shell
when mwan3 is called with 'mwna3 restart`.
`Error: Invalid gateway address.`
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
[aaronjg@stanford.edu: fully unset variable and handle ipv4 as well]
Signed-off-by: Aaron Goodman <aaronjg@stanford.edu>
(cherry picked from commit 8e3e6f8dde)
Add double quote to prevent globbing and word splitting where there is
no regression.
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
(cherry picked from commit feae9e5742)
This suppress the following output on `mwan3 restart`:
> Dump terminated
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
(cherry picked from commit facf8ea299)
If the status file is not found then set then return the value unknown.
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
(cherry picked from commit e30f16beef)
Till now we could only ping http targets on port 80. With this change by
adding the config boolean config option httping_ssl we could also ping
https ping targets on port 443.
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
(cherry picked from commit a689e168aa)
The variable IPT is not valid at this point. Set the variable usage to IPT4
fixes this issue.
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
(cherry picked from commit 581d7df844)
The only action the Threshold plugin takes itself is to generate and
dispatch a notification. Other plugins can register to receive
notifications and perform appropriate further actions.
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
(cherry-picked for 19.07, line numbers adjusted)
Signed-off-by: Hannu Nyman <hannu.nyman@iki.fi>
Redmine-patch-id: 3680
If I build an image with the imagebuilder I get the following output
during image building:
../root-x86/etc/init.d/collectd: line 4: /usr/share/libubox/jshn.sh:
No such file or directory
To remove this messsage move include to the needed postion, so that the
message does not occur during image building on the host system anymore.
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
(cherry-picked, modified to match 19.07)
Signed-off-by: Hannu Nyman <hannu.nyman@iki.fi>
Since the merge of the luci master branch into the luci openwrt.19.07 branch,
the ubus API was not in sync anymore. So all commits from the master
branch where backported into the openwrt-19.07 branch. But this could
not be done linear. There were already some fixes cherry-picked from the
master and the version does not match anymore. This commit syncronized
the PKG_VERSION and the PKG_RELEASE again to make clear that the
version in master and openwrt-19.07 are even again and have so the
same software version until to this commit.
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
With this change it is now possible to combine interface action events.
If an interface action is generated by netifd or mwan3 for example ifup,
ifdown, connectd or disconnected and this action is configured in the inteface
uci section, then the conntrack table is flushed by mwan3.
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
Update to latest stable release 5.54
Add new options ticketKeySecret and ticketMacSecret to uci validation.
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
If you want to register more than one lua plugin, you cannot start the
collectd.
You get always the error message:
"The read function "lua/(null)" is already registered. Check for
duplicates in your configuration!"
This is not what I expect and what the documenation says.
With this change it is now possible to registrate more then one lua
Script.
See https://github.com/collectd/collectd/pull/2379
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
Before this change two disconnected events were generated. This is wrong!
The disconnected event is impliciet generated by the hotplug script on ifdown
event. The mwan3track script is notified by a USR1 signal which
generates the disconnectd event. The additional "disconnectd" event on
ifdown is not required.
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
Add to ubus the missing output information "policies" which could already
be observed with the command "mwan3 status".
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
If we set the option "local_source" in the globals mwan3 section to "none",
traffic generated by the router it self will always use the default route from
the wan interface with the lowest metric. If this interface is down
the router traffic still uses the connection with the lowest metric but
this is disconnected. Load balancing and failover from the lan site is
still possible. Only router generated traffic is not load balanced and
could not use failover.
To solve this issue with router initiated traffic add the additional
option "online_metric" to the mwan3 interface section.
If the interface is connected then this lower "online metric" is set in the
default routing table.
With this change we have at least a failover with router initiated
traffic.
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
During runntime of mwan3 we could add dynamicly networks to this ipset
which would then treated as connected networks by mwan3.
This is also usefull for ipsec.
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
With the list param "rt_table_lookup" in the mwan3 section globals,
it is now possible to add a additional routing table numbers which would get
also parsed and will be added to the connected network.
So mwan3 will treat them as they are directly connected to this device.
This could be usefull if we use ipsec.
Signed-off-by: Florian Eckert <fe@dev.tdt.de>