Commit Graph
28 Commits
Author SHA1 Message Date
Florian Eckert 085a76bebf net/mwan3: update version
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
2017-06-22 13:42:14 +02:00
Florian Eckert 99229475b7 net/mwan3: simplify tracking status statement command
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
2017-06-22 13:42:14 +02:00
Florian Eckert b6e9debc1b net/mwan3: add lock for mwan3 hotplug script
If more then one interface get up/down at once mwan3 could be in a
undefined state, because more then one mwan3 hotplug script are running
and editing the iptables.

Lock the critical section should solve this issue.

Signed-off-by: Florian Eckert <fe@dev.tdt.de>
2017-06-22 13:42:12 +02:00
Florian Eckert f35475c025 net/mwan3: update Makefile version
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
2017-05-12 15:30:34 +02:00
Florian Eckert db5ea39c9b net/mwan3: generate mwan3track run path folder on every run
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
2017-05-12 15:30:34 +02:00
Florian Eckert ef3261d0b4 net/mwan3: remove absolute path for bin files
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
2017-05-12 15:28:12 +02:00
Florian Eckert 1fd3f85d4f net/mwan3: remove pid file use pgrep to get pid
If mwan3track will not stop immediately after sending the kill signal,
the clean_up handler will delete the pid file later while the new mwan3track is
already running.

This could result in a situation that mwan3track is running
more then once because the old mwan3track service could not be killed,
because the pid file is missing.

Using pgrep to kill all mwan3track for the tracked interface and not using
pid file should fix this issue.

Signed-off-by: Florian Eckert <fe@dev.tdt.de>
2017-05-12 15:28:12 +02:00
Florian Eckert c8f8f77ed1 net/mwan3: update Makefile version
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
2017-04-27 11:48:15 +02:00
Florian Eckert f94975b71f net/mwan3: add connected network regardless of mwan3 interface enable state
If netifd set an interface up/down which is not tracked by mwan3 the
connected network of that interface should regardless be added/removed to the
mwan3_connected ipset.

Signed-off-by: Florian Eckert <fe@dev.tdt.de>
2017-04-27 11:44:49 +02:00
Florian Eckert 45437dc7c9 net/mwan3: update Makefile version
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
2017-04-11 09:46:20 +02:00
Florian Eckert 7e80e83dfd net/mwan3: mwan3track interrupt sleep on signal (trap) event
Sleep will be aborted if a signal is send to this process.

Signed-off-by: Florian Eckert <fe@dev.tdt.de>
2017-04-11 09:46:20 +02:00
Florian Eckert b216fd3642 net/mwan3: registrate SIGUSR1 trap on interface down event
If interface is getting down by netifd (unplug ethernet cable)
mwan3track will not recognize this change. It will also generate an
additional down event when he notice does his tracking interface is offline.

Mwan3track will now be informed by a signal (trap) USR1 during down event
that the interface is already down. An additional down event will not be
generated.

Signed-off-by: Florian Eckert <fe@dev.tdt.de>
2017-04-11 09:46:20 +02:00
Florian Eckert 84df06e0dc net/mwan3: add status track ubus interface
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
2017-04-11 09:46:20 +02:00
Florian Eckert 4d8d889ced net/mwan3: update Makefile version
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
2017-04-05 07:29:45 +02:00
Florian Eckert 6bb84f69e7 net/mwan3: decrease parameter invocation of mwan3track
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
2017-04-05 07:29:45 +02:00
Florian Eckert 5b55223d80 net/mwan3: add clean_up trap function for SIGINT SIGTERM
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
2017-04-04 16:00:06 +02:00
Florian Eckert 51367883fc net/mwan3: unify logging in mwan3track
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
2017-04-04 15:33:37 +02:00
Florian Eckert 23339d7ae1 net/mwan3: move global mwan3track into main function
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
2017-04-04 15:01:34 +02:00
Florian Eckert ae335e7384 net/mwan3: add failure and recovery interval
If mwan3track detects a failure the interval check will change to
"failure_interval" value until this interface is declared "offline".
After interface gets "offline" normal "interval" value is used again.
If interface ping is successful again "recovery_interval" value is used until
interface is declared "online" again.

Using the different intervals will accelerate the wan line detections on
failure and recovery.

Signed-off-by: Florian Eckert <fe@dev.tdt.de>
2017-03-27 08:45:13 +02:00
Florian Eckert 5cacfd34a6 net/mwan3: add ubus interface check
On interfaces with interface proto "qmi|ncm" and option dhcp
enabled the interface will be changed to $iface_4 | $iface_6. The
interface mapping in mwan3 will not recognize this interface. To fix
this issue an ubus call will check if an upper interface exists.

Signed-off-by: Florian Eckert <fe@dev.tdt.de>
2017-03-21 08:59:31 +01:00
Florian Eckert 3f79fcb756 net/mwan3: pass environment variables to mwan3-user
User scripts conversion from luci-app-wan3 will be simplified if the variables
are passed by env instead of arguments.

Signed-off-by: Florian Eckert <fe@dev.tdt.de>
2017-03-21 08:31:06 +01:00
Florian Eckert 415c405061 net/mwan3: change maintainer
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
2017-03-20 08:48:16 +01:00
Florian Eckert 75a5237029 net/mwan3: fix track_ips count
fix track_ips generation introduced with commit
6d44a7679a

Signed-off-by: Florian Eckert <fe@dev.tdt.de>
2017-03-20 08:39:18 +01:00
Florian Eckert 43ca6ec481 net/mwan3: add mwan3.user hotplug script
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
2017-03-17 12:33:45 +01:00
Florian Eckert 28c8b664e4 net/mwan3: fix hotplug on ACTION ifdown
On dynamic interface proto (dhcp/pppoe) the hotplug will not execude (exit 9)
because the gateway is already released. The check will now only be made
on a ifup ACTION event.

Signed-off-by: Florian Eckert <fe@dev.tdt.de>
2017-03-17 11:06:29 +01:00
Florian Eckert 6d44a7679a net/mwan3: add ping size option to mwan3track
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
2017-03-16 10:01:07 +01:00
Florian Eckert 3231736cab net/mwan3: reset conntrack table on iface up/down event
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
2017-03-16 10:01:06 +01:00
Florian Eckert ec3349a8a4 net/mwan3: add me as co maintainer
Signed-off-by: Florian Eckert <fe@dev.tdt.de>
2017-03-08 10:42:36 +01:00